Product Information

Filter Media

Chlorine Cutter Fe&Mn

Chlorine(Cl2)

Iron (Fe)

Manganese

Chlorine Cutter Fe and Chlorine Cutter Mn are made from chamotte and ceramic GT, which are made by granulating, crushing and sieving natural granulated pumice stones and fireclay, and coated with iron oxyhydroxide and manganese dioxide.
Since they have a myriad of ventilation pores and excellent adsorption, they are used for removing iron and manganese.

Chlorine Cutter Fe

CHLORINE CUTTER Fe eliminates iron with oxygen dissolved as an oxidant while filter media are used as a catalyst. 
No hypochlorous acid, bromic acid, or THM are produced.
Removal of iron and manganese without chlorine is possible if used together with “Chlorine Cutter Mn”.

FEATURES

  1. Oxidation of Metal uses the oxygen in the air.
  2. Chloric acid, bromic acid, trihalomethane and so on are not created since the chlorine is not used.
  3. There is no cost for the running of chemical.

PROPERTIES

AppearancePrincipal IngredientEffective Size
(mm)
True Density
(g/cm³)
 Bulk Density
(g/cm³)
YELLOW BROWIron hydroxide 0.60~1.401.80~2.150.55~0.80


Chlorine Cutter Mn

Manganese removing media without chlorine
Chlorine Cutter Mn has a removal mechanism by a direct oxidation process which is fundamentally different from the traditional removing process with special filter media. There is no need to control residual chlorine as sodium hypochlorite is not used. Furthermore, manganese removal is not affected by concentration and type of residual chlorine.

FEATURES

  1. Reduction of chloric acid and bromic acid
    If ammonia nitrogen is contained, the reduction amount is increased in comparison with the contact oxidation. [Rate (mg/L) of in Chlorine amount for contact oxidation = ammonia nitrogen (mg/L) × 10 (Approx.)]
  2. Reduction of running cost for chemical
    If ammonia nitrogen is contained, the reduction amount is increased in comparison with the contact oxidation. [The comparison (JPY) between rate of chlorine injection amount and usage amount of regenerate agent for the Treated water 1m³ (Cubic Meter)]
  3. No need to control the residual chlorine
    There is no need to control the residual chlorine since sodium hypochlorite is not normally used. The capacity of demanganization of Chlorine Cutter Mn does not influence the concentration of chlorine and residual chlorine (free chlorine and combined chlorine) like the contact oxidation. The contact oxidation is difficult for demanganization treatment to control the concentration of effective free chlorine due to a lot of changes in case ammonia nitrogen is contained.

PROPERTIES

AppearancePrincipal Ingredient Effective Size
(mm)
True Density
(g/cm³)
Bulk Density
(g/cm³)
BLACKManganese dioxide0.352.6~2.750.95~1.05
Product Information

Click below

Contact